Ticket #530 (closed defect: fixed)
Opened 2011-05-20T14:03:56-05:00
Last modified 2012-02-24T16:51:25-06:00
Make legacy harmonization bidirectional
Reported by: | bdezonia | Owned by: | bdezonia |
---|---|---|---|
Priority: | major | Milestone: |
|
Component: | Legacy Compatibility | Version: | |
Severity: | serious | Keywords: | |
Cc: | Blocked By: | ||
Blocking: | #1011 |
Description
From previous instantiations of IJ1 plugins there may be a remembered association between a Dataset and an ImagePlus. If the Dataset is changed by IJ2 then the mapping is unsynchronized. We need to update all existing ImagePluses who are associated with the Datasets being sent as inputs to each invocation of a legacy plugin.
Must change LegacyPlugin (or perhaps PlugginRunner) to call the DatasetHarmonizer both before and after the call to a plugin. DatsetHarmonizer must be updated to handle bidirectional translation and as efficiently as possible.
Change History
comment:1 Changed 2011-05-23T14:42:02-05:00 by bdezonia
- Status changed from new to closed
- Resolution set to fixed
comment:2 Changed 2011-05-23T14:42:10-05:00 by bdezonia
- Status changed from closed to reopened
- Resolution fixed deleted
comment:3 Changed 2011-05-23T14:42:21-05:00 by bdezonia
- Status changed from reopened to closed
- Resolution set to fixed
Initial implementation in 1a3c034a8d2f4436ab57f3e9b00aa9022cdc3ac1. Some enhancements maybe desirable. Will hatch new tickets for that.